3 PHASE LIFT INVERTER

3 PHASE LIFT INVERTER
5 KVA - 100 KVA

  • Regulated output voltage and frequency for smooth and quite operation of AC motors and other inductive and capacitive loads
  • Surge capability load up to 300%
  • Smart LCD panel display for battery voltage and load percentage
  • Protections like over temperature, short circuit, battery low/high cut, overload
  • Low maintenance cost

Brochure User Manual Enquiry

Features

  • State of art IGBT based PWM technology to increase Crest Factor Tolerance & Dynamic Stability.
  • High Inrush capability to handle Lift during Startup
  • Very Low Total Harmonic Distortion <3%.
  • All necessary Protection like Short Circuit, Over Temp., Battery Low/High, Mains MCB Tripped etc. with Comprehensive display.
  • 100% Pure, Reliable and Regulated Power
  • Unbalanced Load Handling Capability
  • Runs heavy duty appliances/equipments.
  • Extended overload capability (upto 300%)
  • Start up without Mains (Cold start)
  • Generator compatible
  • Extended power backup time
  • Built in Galvanic Isolation Transformer

Applications

  • Industrial drives and motors
  • Petrol pumps
  • BPO/Call centers
  • Deep freezers
  • Elevators & Escalators
  • Laboratories
  • Textile Industry
  • Restaurants and Hotels
  • Clubs/Pubs
  • Welding arcs

Specification

TYPE 3 Phase Input - 3 Phase Output
Model POWER SERIES
Capacity 5 KVA TO 50 KVA
INPUT  
No. of Phases 3 Phase - 4 Wire
Voltage Range 310 V - 480 Volts AC
Input Frequency Range 45 to 55Hz.
OUTPUT  
Load PF Range 0.8 lagging
Phase 3 Phase - 4 Wire
Output Waveform Pure Sine Wave
Voltage 400 V ± - 2%
Frequency 50Hz ± - 0.1%
Load Crest Factor > 4 :1
Output Voltage THD <=3% on Linear Load
Loading Capacity 110% for 2 Minutes
Transient Recovery ± 4% under full load change and corrected within 5 cycles
Phase Desplacement 120 ± 1
Over Load Capacity 105% continuos, 300% for 60 sec
BY-PASS  
Maintenance By-Pass Available
BATTERY  
No. of 12V Batteries 5 & 7.5 KVA ( 10 )  -  10 & 15 KVA ( 15 )  -  20 & 25 KVA ( 20 )  -  30 TO 50 KVA ( 30 )
Voltage 120 VDC - 360 VDC
Battery Charging Current 1 Amp to 10 Amp
Battery Recommendation From 26 Ah to 200 Ah
GENERAL PARAMETERS  
Indication All parameter shown in LCD panel & LED indicators
Protection Output Overload & Short circuit, Output under & Overvoltage
DC Under & Overvoltage, Single Phasing & Phase unbalance (for 3 - Ph Input only)
Protection Short Circuit, Thermal, Battery Low/High, Mains high/low,output high/low, overload
Cooling Forced Air Cooling
UPS Efficiency > 95%
Working Environment Temp: -10~40ºC,  relative humidity: 30%~90%
Accoustic Noise Less than 55 dB at 1 Meter